U.S. flag

An official website of the United States government

Format

Send to:

Choose Destination

SRX317820: GSM1173002: UACC812 Exome-Seq; Homo sapiens; OTHER
1 ILLUMINA (Illumina Genome Analyzer IIx) run: 63.3M spots, 12.5G bases, 6.2Gb downloads

Submitted by: Gene Expression Omnibus (GEO)
Study: Exome sequencing of a panel of breast cancer cell lines to identify mutations
show Abstracthide Abstract
This information was used to identify mutations associated with particular breast cancer subtypes, as well as associations with response to therapy. Overall design: 75 breast cancer cell lines underwent exome sequencing to identify mutations.
Sample: UACC812 Exome-Seq
SAMN02225515 • SRS454805 • All experiments • All runs
Organism: Homo sapiens
Library:
Instrument: Illumina Genome Analyzer IIx
Strategy: OTHER
Source: GENOMIC
Selection: other
Layout: SINGLE
Construction protocol: Qiagen Gentra Puregene Cell Kit Exome libraries of matched pairs of tumour / normal genomic DNAs were generated using the Agilent SureSelect XT kit and Agilent Automation Systems NGS system per manufacturer’s instructions. 1 ug of each genomic DNA was sheared using a Covaris E220 to a peak target size of 150 bp. Fragmented DNA was concentrated using AMPureXP beads (Beckman Coulter), and DNA ends were repaired using T4 DNA polymerase, Klenow polymerase, and T4 polynucleotide kinase. 3’ A-tailing with exo-minus Klenow polymerase was followed by ligation of Agilent paired-end oligo adapters to the genomic DNA fragment. Ligated DNA was PCR amplified for 8 cycles and purified using AMPure XP beads and quantitated using the Quant-It BR kit (Invitrogen). 500 ng of sample libraries were hybridized to the Agilent biotinylated SureSelect 37Mb Capture Library at 65°C for 72 hr following the manuufacturer’s protocol. The targeted exon fragments were captured on Dynabeads MyOne Strepavidin T1 (Invitrogen), washed, eluted, and enriched by amplification with Agilent post-capture primer and an indexed reverse primer for multiplexing12 additional cycles. After purification of the PCR products with AMPure XP beads, the quality and quantity of the resulting exome libraries were analyzed using an Agilent Bioanalyzer High Sensitivity chip.
Experiment attributes:
GEO Accession: GSM1173002
Links:
External link:
Runs: 1 run, 63.3M spots, 12.5G bases, 6.2Gb
Run# of Spots# of BasesSizePublished
SRR92581363,313,52112.5G6.2Gb2013-08-28

ID:
443355

Supplemental Content

Recent activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...